Home > Software > EEG/Qeeg Software > Thought Technology Ltd. >
SCP Suite - Slow Cortical Potentials by Thought Technology  - SWR-SA7985
SCP Suite - Slow Cortical Potentials by Thought Technology  - SWR-SA7985
SCP Suite - Slow Cortical Potentials by Thought Technology  - SWR-SA7985
You may also be interested in these:
DC- EEG Mono Polar / Bi Polar Kit Mono Polar,Bi Polar,monpolar,bipolar,DC electrode, DC,silver silver chloride,Electrodes,eeg,nuerofeedback,electrodes,Thought Techology,neurofeedback supplies,biofeedback supplies,eeg supplies
Unigel Electrode for snap connetion
TT- AV Sync by Thought Technology
TT 27" Extender Cables for EMG/EKG electrodes EKG,ekg extender cable,ekg electrode extender cable,emg,emg electrodes, emg electrode extender cable,extender cablehrv,bvp,semg,HEG,pIR,HRV,thoughttechnology,thought technology,thoughttech,thoughtech,thoughttek,eeger,eeger software
ProComp 5 by Thought Technology  ProComp5,Infiniti,ProComp5 Infiniti,thought techhnology,neurofeedback,biofeedback,emg,hrv,bvp,semg,HEG,pIR,
ProComp Infiniti 8 channel
EEG-Z3™ Sensor - low freq, SCP            EEG-Z3 sensor,eeg-z3,eegz3,EEG Z,eegz,Thought Technology,electroencephalograph,BioGraph,eeg,biofeedback,thoughttechnology,thought technology,thoughttech,thoughtech,thoughttek
EEG Z Sensor for EEG by Thought Technology Flex,pro, eeg, eeg sensor, impedance, neurofeedback, thought technology, flex pro, eeg-z, thought technology

SCP Suite - Slow Cortical Potentials by Thought Technology

Item #: SWR-SA7985
Availability: In Stock
Usually ships In 1-3 Business Days
Price: $355.00




    Enter your Encoder Serial Number Here (6 letter/number combo on bottom of your encoder) * Max: 6 character(s)

    Quantity:

    Download links usually sent within 2 business days

    The SCP Suite is a complete training system for clinicians wanting to add the benefits of Slow Cortical Potentials training into their practice. By combining pioneering research & decades of clinical experience into one simple package, the SCP Suite brings all of the benefits of SCP training to you.

    For use with ProComp 5 or ProComp Infiniti, EEGZ sensor, EEGZ 3 sensor, Extender cable, unigel electrodes, silver/silver chloride electodes, and TT-AV Sync.

    See the manual here.

    From a complex science, to a simple solution.

    Reliably extracting Slow Cortical Potentials from raw EEG is a complex science. Each event-triggered SCP must be measured with millisecond accuracy & properly controlled for artifacts. Anything less is simply unreliable. Using state-of-the-art technology, the SCP Suite ensures that recorded SCPs are of the highest quality.

    • Fully-automated program
    • Peer-reviewed protocols
    • Research-grade accuracy
    • Simple, affordable & easy-to-use system

    Training EEG, bi-directionally!

    The SCP Suite teaches self-regulation of Slow Cortical Potentials in both directions enabling learning of activation as well as inhibition of overall neural activity. The SCP Suite’s fully-automated & bidirectional protocols will empower your clients to gain confident control over their general brain state.

    Review your progress, encourage your success

    With each session of the program, print out your client’s detailed report to review their progress, each and every step of the way.

    For use with ProComp 5 or ProComp Infiniti, BioGraph 6 software, EEGZ sensor, EEGZ 3 sensor, Extender cable, unigel electrodes, silver/silver chloride electodes, and TT-AV Sync.

    SCP Software Suite Manual

    Thought Technology Ltd.
    8205 Montreal-Toronto Blvd. Suite 223, Montreal West Quebec , H4X 1N1 Canada
    Tel: 800-361-3651 (514) 489-8251 Fax: (514) 489-8255
    Email: mail@thoughttechnology.com
    www.thoughttechnology.com

    Exclusive DataLock Technology with Optimal Signal Quality

    One of BioGraph’s key design principles has always been to put your data’s safety first. The system is crash proof and ensures optimal signal quality. Highly accurate sensors and low noise cables ensures quality signals so you can focus on your work. Electrode impedance and arti­fact rejection are essential to clinical work. If you cannot rely on quality sensor data, you cannot ensure valid statistical analysis or demonstrate positive clinical outcomes. BioGraph Infiniti v6.0 runs on the most versatile and reli­able equipment on the market.

    BioGraph Infiniti PC System Requirements:
    Minimum Recommended Processor 1.8 GHz, Dual-core CPU Quad-core CPU, Intel i5

    Operating systems (supported) (32 and 64 bit versions) - Microsoft® Windows® 8, Pro, Enterprise - Microsoft® Windows® 7 Home Premium, Professional, Enterprise or Ultimate with SP1. - Microsoft® Windows Vista® Home Basic, Home Premium, Business, Ultimate, or Enterprise with Service Pack 2. - Microsoft® Windows® XP Prof. or Home Ed.with SP3.

    Memory (RAM):
    3 GB (Vista® or Windows® 7/8/10)

    Hard Disk space:
    50 GB or more, to save video and sessions data

    Video / Graphics card with at least 1 GB of dedicated memory. (Example: ATI Radeon 5770, with 1280x1024 resolution and dual monitor support.)

    Monitor: Two monitors which support resolution of 1280x1024 and higher.

    Other necessary components:

    • DVD-ROM drive.
    • Adequate number of USB ports depending on the intended system usage (1-4 for Pro/Flex Infiniti encoders, 2 for webcams, 1 for TT AV Sync, mouse, keyboard, printer)
    • Mouse or any other compatible pointing device.
    • 32-bit compatible sound card & speakers.
    • Compact Flash Reader (for use with compact flash
    • Up to two webcams with built-in microphone (if recording video). Frame rate 30fps, Microsoft® recommended.
    • Microsoft® Office with Word® and Excel® (for report generation and printing).
    • High-speed Internet access (for updating software and receiving technical support).

    PLEASE NOTE:

    • Tele-Infiniti CF (T9600) version 3.2.1 or higher is compatible with 64-bit Windows® operating systems. Version 3.1 or lower is compatible with 32-bit Windows®.
    • Low speed CPUs (1.8 GB) may be sluggish when running screens with a large number of instruments per screen.
    • If using 2 webcams for video recording, it is strongly suggested to use recommended PC requirements.
    • If using TT-AV Sync functionality, please refer to possibly additional system requirements from appropriate suite manual.

    The following apply to BioGraph Infiniti 6.1 and its application suites:

    • BioGraph Infiniti is a 32-bit software program.
    • BioGraph Infiniti software and application suites are installed for All Users on a per-machine basis.
    • The BioGraph Infiniti system must be installed on the PC where the database is/will be located.
    • BioGraph Infiniti is not designed for use in a networked environment.
    • EEG Sales LLC
    • 800-400-0334
    • info@eegsales.com

    Shop EEG Sales

    EEG Sales LLC offers a full and comprehensive list of quality products and supplies at competitively discounted prices for practitioners of Neurofeedback and Biofeedback. EEG Sales is an authorized distributor for Thought Technology and an authorized reseller for BrainMaster Technologies. We are proud to offer IMA Electronics hand-crafted electrodes and many of the finest equipment and supply brands available. Customer service and quality of product are top priorities with EEG Sales.

    PayPal Acceptance Mark